Minumum and Maximum Cord Lengths Per Voltage Input
V
oltages are determined by the measured Voltage level @ the
Bus Bar where the Transformer and Cords are connected while on White
MELODY & BLANCO MIN/MAX VOLTAGE PER CORD LENGTH
CORD LENGTH Min. Voltage Max. Voltage
15 Feet 7.8Vac 12.0Vac
30 Feet 8.6Vac 12.2Vac
50 Feet 9.4Vac 12.4Vac
100 Feet 10.7Vac 13.2Vac
150 Feet 11.82V 13.8Vac
MEL-SOL & BLANCO PRO MIN/MAX VOLTAGE PER CORD LENGTH
CORD LENGTH Min. Voltage Max. Voltage
20 Feet 9.8Vac 12.0Vac
30 Feet 9.92Vac 12.2Vac
50 Feet 10.34Vac 12.56Vac
100 Feet 10.9Vac 13.5Vac
150 Feet 11.43Vac 14.1Vac
SAVI Pool and Spa provides these guidelines as a reference for proper operation. Failure to adhere
specifications could result in improper operation or synchronization of lights.
ALL VOLTAGE READINGS ARE TAKEN WHILE LIGHTS ARE ALL SET TO WHITE
As these Charts address the Minimum - please remember that at no time should the MAXIMUM
distance with or without J Box extend past 150 ft.
9400 SOUTHRIDGE PARK COURT SUITE 200 ORLANDO, FLORIDA 32819 USA
Tel:407.855.5630      Fax:407.210.8679     nextstepproduct.com